Showing all 318 results

GE / ITI PCL Series – AC Current Transducer

  • Input: Up to 75 AAC
  • Output: 4-20 mADC
  • Frequency: 50-60 Hz
  • Insulation Level: 600 V, 10 kV BIL full wave

GE / ITI PCM Series – AC Current Transducer

  • Input: Up to 300 AAC
  • Output: 4-20 mADC
  • Frequency: 50-400 Hz
  • Insulation Level: 600 V, 10 kV BIL full wave

GE / ITI 100 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 110 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 112, 113, 114, 115, & 117 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.25″, 2.75″, 3.25″, 4.00″ & 4.62″
  • Available in Multi-Ratio (MR)

GE / ITI 12 & 13 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.37″ & 0.56″

GE / ITI 120 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 125 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.31″

GE / ITI 126 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.25″

GE / ITI 130 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″

GE / ITI 135 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 137 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.50″
  • Available in Multi-Ratio (MR)

GE / ITI 139 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Available in Multi-Ratio (MR)

GE / ITI 14, 15 & 16 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.64″, 0.94″ & 1.25″

GE / ITI 140 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 141 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″
  • Available in Multi-Ratio (MR)

GE / ITI 142 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.25″
  • Available in Multi-Ratio (MR)

GE / ITI 143 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.31″
  • Available in Multi-Ratio (MR)

GE / ITI 144 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 145 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.00″
  • Available in Multi-Ratio (MR)

GE / ITI 146 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.75″

GE / ITI 147 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 10.00″

GE / ITI 170 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 180 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 183 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″

GE / ITI 19 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI 191, 192, 193, 194 & 195 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.75″, 2.13″, 2.50″, 3.06″

GE / ITI 2 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″, 1.13″

GE / ITI 200, 201, 202, 203 & 204 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″, 3.50″, 4.88″, 5.25″, 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 21, 22, 23, 24 & 25 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″, 1.63″, 2.00″, 2.50″ & 3.13″

GE / ITI 296, 297, 298, 299 & 300 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.50″, 2.25″, 3.00″, 3.38″ & 3.75″

GE / ITI 2DARL Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.00″

GE / ITI 2VT460 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X

GE / ITI 2VT469 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: + 1% at all burdens up to 5 VA at 1.0 and 0.95 P.F.

GE / ITI 306 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 307 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 308 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 309 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 311MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Multi-Ratio (MR)

GE / ITI 386 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 387 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.50″
  • Available in Multi-Ratio (MR)

GE / ITI 388 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 389 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.75″
  • Available in Multi-Ratio (MR)

GE / ITI 3CPT3-60-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/13.0 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI 3CPT3-60-30 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 30.0 kVA at 30C/25.7 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI 3CPT3-60-45 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 45.0 kVA at 30C/38.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI 3CPT5-95-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/13.0 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI 3CPT5-95-30 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 30.0 kVA at 30C/35.7 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI 3CPT5-95-45 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 45.0 kVA at 30C/38.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI 3CPTD3-60-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI 3CPTD5-95-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI Model 401, 402, 403, 404, 405 – Low Voltage Control Power Transformers

  • Thermal Rating: 1-5 kVA/40°C
  • Frequency: 60 Hz
  • Secondary Voltage: 240 Volts with center tap
  • Insulation Level: 0.6 kV, Class H (180°C)

GE / ITI 3CPTDV3-60-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI 3CPTDV5-95-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI 3P1 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.31″

GE / ITI 3P10 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.58″ x 0.26″

GE / ITI 3P18 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.19″

GE / ITI 3P2 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.69″

GE / ITI 3P27 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.44″x 0.44″

GE / ITI 3P28 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″x 0.82″

GE / ITI 3P3 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.97″

GE / ITI 3P30 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.88″

GE / ITI 3P4 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″

GE / ITI 3P40 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.75″

GE / ITI 3P41 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.03″

GE / ITI 3P42 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.50″

GE / ITI 3P43 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.00″

GE / ITI 3P5 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″

GE / ITI 3P528 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.33″ x 5.20″

GE / ITI 3P56 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.13″

GE / ITI 3P665 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.63″ x 4.88″

GE / ITI 3P667 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″

GE / ITI 3P668 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.66″

GE / ITI 3P669 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.87″ x 6.30″

GE / ITI 3P670 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.88″

GE / ITI 3P80 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.00″

GE / ITI 3P81 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P82 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″

GE / ITI 3P83 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.45″

GE / ITI 3P84 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.05″ x 0.50″

GE / ITI 3P85 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.08″

GE / ITI 3P86 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.55″ x 0.25″

GE / ITI 3P9 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.25″ x 0.25″ Full Radius

GE / ITI 3P90 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.63″

GE / ITI 3P91 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.12″

GE / ITI 3P92 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.56″ x 2.12″

GE / ITI 3P93 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.88″

GE / ITI 3VT468 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 75 VA at 30C/50 VA at 55C
  • Accuracy Class: ± 0.6% @ 7.5 VA

GE / ITI 3VT471 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: ±1% @ 5 VA

GE / ITI PT6 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 25.5 kV, BIL 125 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG3 & PTW3 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 5.6 kV, BIL 60 kV
  • Thermal Rating: 750 VA at 30C/500 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.6 WX, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG4 & PTW4 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 9.52 kV, BIL 75 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI PTG5 & PTW5 Series – Indoor Medium Voltage Transformers

  • Frequency: 60 Hz
  • Maximum System Voltage: 15.5 kV, BIL 110 kV
  • Thermal Rating: 1500 VA at 30C/1000 VA at 55C
  • Accuracy Class: 0.3 WXMY,1.2 Z at 100 % rated voltage with 120 V based ANSI burden.
    0.3 WXMY, 1.2 MY at 58 % rated voltage with 69.3 V based ANSI burden.

GE / ITI 3VT472 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: ± 1% @ 5 VA

GE / ITI 3VTL460 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V line-to-line
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X at 60 Hz

GE / ITI 3VTN460 Series – 3-Phase Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X at 60 Hz

GE / ITI 450 Series – Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 750 VA at 30C/500 VA at 55C
  • Accuracy Class: 0.3 W, X, M & Y, 1.2Z
    Those marked ** are 0.3 W, 0.6 X, M & Y

GE / ITI 450I Series – IEC Rated 50 Hz Voltage Transformers

  • Frequency: 50 Hz
  • Standard Secondary Voltage: 110 Volts
  • Insulation Level: 720 Volts
  • Accuracy Class: 0.2 at 40 VA / 0.5 at 70 VA
  • Thermal Rating: 550 VA at 30C / 350 VA at 55C

GE / ITI 460 Series – Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X at 60 Hz

GE / ITI 460I Series – IEC Rated 50 Hz Voltage Transformers

  • Frequency: 50 Hz
  • Standard Secondary Voltage: 110 Volts
  • Insulation Level: 720 Volts
  • Accuracy Class: 0.5 at 10 VA / 1.0 at 20 VA
  • Thermal Rating: 125 VA at 30C / 75 VA at 55C

GE / ITI 465 Series – Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 150 VA at 30C/100 VA at 55C
  • Accuracy Class: 0.6 W, 1.2 X at 60 Hz

GE / ITI 467 Series – Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 40 VA at 30C/27 VA at 55C
  • Accuracy Class: ± 1% at all burdens up to 5 VA at 1.0 and 0.95 P

GE / ITI 475 Series – Voltage Transformers

  • Frequency: 60 Hz
  • Standard Secondary Voltage: 120 V
  • Insulation Level: 600 V, BIL 10 kV
  • Thermal Rating: 300 VA at 30C/200 VA at 55C
  • Accuracy Class: 0.3 W, 0.6 X, 1.2 M at 60 Hz

GE / ITI 475I Series – IEC Rated 50 Hz Voltage Transformers

  • Frequency: 50 Hz
  • Standard Secondary Voltage: 110 Volts
  • Insulation Level: 720 Volts
  • Accuracy Class: 0.2 at 10 VA / 0.5 at 20 VA
  • Thermal Rating: 225 VA at 30C / 150 VA at 55C

GE / ITI 5 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 500 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: Available up to 10″ x 30″

GE / ITI 510 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.63″ x 8.25″

GE / ITI 520 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.44″ x 1.22″

GE / ITI 521 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″ x 0.59″

GE / ITI 525 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.33″ x 0.59″

GE / ITI 530 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.88″ x 3.06″”

GE / ITI 531 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.06″ x 3.06″

GE / ITI 540, 541, 542 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.53″ x 1.53″, 0.53″x 3.03″, 0.53″x 4.03″

GE / ITI 543, 544, 545, 546, 547, 548 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.53″ x 1.53″, 0.53″x 3.03″, 0.53″x 4.03″

GE / ITI 550 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.1″ to 10.1″ x 7.1″ to 30.1″

GE / ITI 56 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 560 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 4.25″

GE / ITI 561 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 4.25″

GE / ITI 562 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.00″ x 5.38″

GE / ITI 563 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.00″ x 5.38″

GE / ITI 566 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″ x 2.25″

GE / ITI 567 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.75″ x 3.75″

GE / ITI 568 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 7.45″ x 3.75″

GE / ITI 569 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 9.50″ x 3.75″

GE / ITI 570 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.56″ x 0.79″

GE / ITI 571 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.58″ x 4.13″

GE / ITI 572 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.66″ x 4.16″

GE / ITI 573 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.43″ x 5.00″

GE / ITI 574 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 2.25″

GE / ITI 575 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 3.25″

GE / ITI 576 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 5.25″

GE / ITI 577 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 2.25″

GE / ITI 578 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 3.25″

GE / ITI 579 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 5.25″

GE / ITI 58 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.25″

GE / ITI 580 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.50″ x 1.00″

GE / ITI 581 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.13″ x 1.13″

GE / ITI 582 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 3.25″ x 2.00″

GE / ITI 583 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.59″ x 3.12″

GE / ITI 584 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.37″ x 3.15″

GE / ITI 585 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 6.90″ x 3.15″

GE / ITI 586 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.56″ x 3.56″

GE / ITI 590 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.28″ x 11.28″

GE / ITI 592 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.00″ x 14.00″

GE / ITI 593 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.06″ x 22.06″

GE / ITI 594 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.06″ x 20.06″

GE / ITI 595 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.56″ x 13.44″

GE / ITI 596 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.56″ x 17.63″

GE / ITI 5A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 5DARL Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.56″

GE / ITI 6 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 60, 61 & 62 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 0.94″, 1.25″ & 1.56″

GE / ITI 600 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 5.50″

GE / ITI 601 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 4.50″ x 4.50″

GE / ITI 603 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 1.00″, 2.00″ x 2.00″

GE / ITI 604 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.42″ x 1.53″

GE / ITI 606 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.75″ x 2.70″

GE / ITI 608 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.60″ x 6.25″

GE / ITI 610 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.30″ x 1.47″

GE / ITI 613 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.80″ x 1.95″

GE / ITI 614 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 0.75″ x 0.75″

GE / ITI 615 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.31″ x 1.66″

GE / ITI 616 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 1.31″ x 2.16″

GE / ITI 617 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Size: 2.00″ x 3.50″

GE / ITI 622 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.25″

GE / ITI 623 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 624 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.25″

GE / ITI 625 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 680 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″

GE / ITI 681MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″
  • Multi-Ratio (MR)

GE / ITI 682 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.62″

GE / ITI 685 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″

GE / ITI 686MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 7.02″
  • Multi-Ratio (MR)

GE / ITI 6A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.06″

GE / ITI 7 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 76 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 3.00″

GE / ITI 780 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 781MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Multi-Ratio (MR)

GE / ITI 785 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″

GE / ITI 786MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.50″
  • Multi-Ratio (MR)

GE / ITI 788 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″
  • Available in Multi-Ratio (MR)

GE / ITI 790 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 5.00″
  • Available in Multi-Ratio (MR)

GE / ITI 792 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″

GE / ITI 793MR Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.00″
  • Multi-Ratio (MR)

GE / ITI 7A Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 2.50″

GE / ITI 8 Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 3.25″

GE / ITI 95 Series – LED Lighted Control Switches

The series 95 Instrument and Control Switches are heavy duty rotary switches that satisfy the most demanding requirements of Industrial Control and Power Applications.

GE / ITI A & B Series – Low Voltage Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.05″ & 2.06″

GE / ITI CPT3-60-10 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 10.0 kVA at 30C/8.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPT3-60-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/12.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPT3-60-25 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 25.0 kVA at 30C/21.5 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPT3-60-37.5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 37.5 kVA at 30C/32.2 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPT3-60-5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 5.0 kVA at 30C/4.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPT5-95-10 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 10.0 kVA at 30C/8.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPT5-95-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/12.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPT5-95-5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 5.0 kVA at 30C/4.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTD3-60-25 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 25 kVA at 30C/21.5 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTD3-60-37.5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 37.5 kVA at 30C/32.2 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTD3-60-50 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 50.0 kVA at 30C/42.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTD3-60-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTD5-95-25 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 25 kVA at 30C/21.5 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTD5-95-37.5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 37.5 kVA at 30C/32.2 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTD5-95-50 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 50 kVA at 30C/42.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTD5-95-75 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 75.0 kVA at 30C/64.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTD7-150-25 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 25.0 kVA at 30C/21.5 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 34.5 kV, 150 kV BIL full wave

GE / ITI CPTD7-150-37.5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 37.5 kVA at 30C/32.2 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 34.5 kV, 150 kV BIL full wave

GE / ITI CPTD7-150-50 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 50.0 kVA at 30C/42.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 34.5 kV, 150 kV BIL full wave

GE / ITI CPTN5-95-25 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 25.0 kVA at 30C/21.5 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTN5-95-37.5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 37.5 kVA at 30C/32.2 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTS3-60-10 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 10.0 kVA at 30C/8.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTS3-60-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/12.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTS3-60-5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 5.0 kVA at 30C/4.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 5 kV, 60 kV BIL full wave

GE / ITI CPTS5-95-10 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 10.0 kVA at 30C/8.6 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTS5-95-15 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 15.0 kVA at 30C/12.9 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CPTS5-95-5 Series – Medium Voltage Control Power Transformers

  • Thermal Rating: 5.0 kVA at 30C/4.3 kVA at 55C
  • Frequency: 60 Hz
  • Insulation Level: 15 kV, 95 kV BIL full wave

GE / ITI CTO Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: Varies, see spec sheet
  • Voltage: 50-4,000 A
  • Thermal Rating: Varies, see spec sheet
  • Window diameter: 7.00″

GE / ITI CTOR Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: Varies, see spec sheet
  • Voltage: 50-4,000 A
  • Thermal Rating: Varies, see spec sheet
  • Window diameter: 8.44″ x 4.50″

GE / ITI CTW3-60-T10 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 50-600 A
  • Thermal Rating: 1.33 at 30C/1.00 at 55C

GE / ITI CTW3-60-T50 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-600 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTW6-125 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 25.5 kV, BIL 125 kV
  • Voltage: 10-600 A
  • Thermal Rating: 1.50 at 30C/1.33 at 55C

GE / ITI CTW7-150 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 36.5 kV, BIL 150 kV
  • Voltage: 10-600 A
  • Thermal Rating: 1.50 at 30C/1.33 at 55C

GE / ITI CTWH3-60-T100 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH3-A-60-T90 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 5.6 kV, BIL 60 kV
  • Voltage: 5-600 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH4-75-T100 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 9.52 kV, BIL 75 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH5-A-110-T150 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-600 A
  • Thermal Rating: 1.33 at 30C/1.0 at 55C

GE / ITI CTWH5-B-110-T200 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH5-L-110 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 5-600 A
  • Thermal Rating: 1.00 at 30C/0.85 at 55C

GE / ITI CTWH5-S-110 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Voltage: 40-1,200 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI CTWH6-125-T200 Series – Indoor Current Transformers

  • Frequency: 50-400 Hz
  • Insulation Level: 25.5 kV, BIL 125 kV
  • Voltage: 800-3,000 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI FT Series – Test Switches

The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to facilitate testing of substation instrumentation and protection devices from the front of the panel. The make before-break current short circuit feature allows test personnel the convenience of isolating equipment from current transformer circuits.

GE / ITI HGF3C Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 4.25″

GE / ITI HGF5C Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 6.31″

GE / ITI HGF8 Series – Ground Fault Current Transformer

  • Ratio: 50:0.025 A
  • Frequency: 50-400 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 8.13″

GE / ITI JAB-0S RevenueSense Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600-2,000 A
  • Window Diameter: 4.5″ x 3.5″

GE / ITI JAB-0W Encompass Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 500-1,500 A
  • Window Diameter: 4.5″ x 3.5″

GE / ITI JAD-0C-X Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 200-4000 A
  • Window Diameter: Cross-shaped; see spec sheet for exact dimensions

GE / ITI JAD-0S RevenueSense Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600-3,000 A
  • Window Diameter: 5.75″

GE / ITI JAD-0W Encompass Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 1,000-1,500 A
  • Window Diameter: 5.75″

GE / ITI JAI-0C & JAU-0C 600V Series – Low Voltage Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL full wave
  • Window Diameter: 1.05″, 1.10″, 2.06″ & 3.00″

GE / ITI JAK-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 200-3000 A
  • Window Diameter: 1.50″/2.60″/3.062″

GE / ITI JAK-0S RevenueSense Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 400-1,000 A
  • Window Diameter: 3.062″

GE / ITI JAK-0W Encompass Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 100-500 A
  • Window Diameter: 3.062″

GE / ITI JCD-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 1,500-8,000 A
  • Window Diameter: 8.13″

GE / ITI JCP-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-4,000 A
  • Window Diameter: 5.38″

GE / ITI JCR-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-400 A
  • Window Diameter: 1.125″/1.50″/2.00″

GE / ITI JCT-0S RevenueSense Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, 10 kV BIL
  • Current: 600 A
  • Window Diameter: 1.31″

GE / ITI JCW-0C Series – Indoor/Outdoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts
  • Current: 100-800 A
  • Window Diameter: 1.125″/1.50″/2.00″

GE / ITI JE-27C Series – Indoor Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 69.3-600 V
  • Thermal Rating: 150 VA at 30C / 100 VA at 55C

GE / ITI JEV-0C Series – Indoor Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 69.3-600 V
  • Thermal Rating: 300 VA at 30C / 200 VA at 55C

GE / ITI JKM-3 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 5 kV, BIL 60 kV
  • Voltage: 5-800 A
  • Thermal Rating: 1.5 at 30C/1.0 at 55C

GE / ITI JKM-4 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 8.7 kV, BIL 75 kV
  • Voltage: 10-800 A
  • Thermal Rating: 1.5 at 30C/1.0 at 55C

GE / ITI JKM-5 Series – Indoor Current Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 15 kV, BIL 110 kV
  • Voltage: 5-800 A
  • Thermal Rating: Variable, see spec sheet

GE / ITI JVA-0C Series – Indoor/Outdoor Voltage Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 120-600 V
  • Thermal Rating: 500 VA at 30C / 300 VA at 55C

GE / ITI JVF-0C Series – Indoor/Outdoor Voltage Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 120-600 V
  • Thermal Rating: 300 VA at 30C / 200 VA at 55C

GE / ITI JVM-0C Series – Indoor/Outdoor Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 69.3-600 V
  • Thermal Rating: 750 VA at 30C / 500 VA at 55C

GE / ITI JVM-2C/3C Series – Indoor Voltage Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: BIL 60 kV
  • Voltage: 2,400-4,800 V
  • Thermal Rating: 750 VA at 30C/500 VA at 55C

GE / ITI JVM-4AC/5AC Series – Indoor High Accuracy Voltage Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: BIL 75-110 kV
  • Voltage: 4,200-14,400 V
  • Thermal Rating: 2,000 VA at 30C/1,400 VA at 55C

GE / ITI JVM-4C/5C Series – Indoor Voltage Transformers

  • Frequency: 50-60 Hz
  • Insulation Level: BIL 75-110 kV
  • Voltage: 4,200-14,400 V
  • Thermal Rating: 1,500 VA at 30C/1,000 VA at 55C

GE / ITI JVW-110C Series – Outdoor High Accuracy Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Primary Voltage: 7,200-14,400 V
  • Thermal Rating: 1,000 VA at 30C/750 VA at 55C

GE / ITI JVW-5AC-1 Series – Outdoor High Accuracy Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Primary Voltage: 7,200-14,400 V
  • Thermal Rating: 1,500 VA at 30C

GE / ITI JVW-5C Series – Outdoor Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 15.5 kV, BIL 110 kV
  • Primary Voltage: 7,200-14,400 V
  • Thermal Rating: 1,500 VA at 30C

GE / ITI PTM-0 Series – Indoor/Outdoor Voltage Transformers

  • Frequency: 60 Hz
  • Insulation Level: 600 Volts, BIL 10 kV
  • Primary Voltage: 120-600 V
  • Thermal Rating: 200 VA at 30C

GE / ITI RT Series – Rack Mount Test Switches

RT switch assemblies for rack and switchboard mounting permit convenient isolation of switchboard relays, meters and instruments. RT racks allow quick and easy multi-circuit testing by conventional test methods.

GE / ITI SB-1 Series – Control & Transfer Switches

Type SB-1 Switches are rotary, cam-operated devices for the control of electrically operated circuit breakers, small motors, magnetic switches and similar devices.

GE / ITI SB-10 Series – Control & Transfer Switches

The SB-10 switch provides two electrically separate and mechanically independent switches in one device. It utilizes both lateral and rotary contacts all constructed on the same switch.

GE / ITI SB-9 Series – Master Control Switches

The SB-9 master control switches are recommended for applications requiring a large number of repetitive operations with positive positioning on each operation.

GE / ITI SBM Series – Control & Transfer Switches

The SBM switch is a rotary cam-operated device for panel mounting and for applications where space is at a premium.