Showing 11–20 of 112 results

Yokogawa AQ6360 – Telecom Optical Spectrum Analyzers

  • Wavelength range: 1200 to 1650 nm
  • Wavelength resolution: 0.1 to 2 nm
  • High wavelength accuracy: ±0.02 nm
  • High dynamic range: 55 dB
  • Wide measurement range: +20 to −80 dBm

Yokogawa AQ6370D – Telecom Optical Spectrum Analyzers

Notice: This product has been discontinued.
Replaced by: AQ6370E
  • Wavelength range: 600 to 1700nm
  • Built-in calibration source
  • High wavelength accuracy: ±0.01nm
  • High wavelength resolution: 0.02nm
  • Wide dynamic range: 78dB typ.
  • Wide level range: +20 to -90dBm
  • Fast measurement: 0.2 sec. (100nm span)
  • Applicable to single-mode and multi-mode fibers

Yokogawa AQ6370E – Telecom Optical Spectrum Analyzers

  • Wavelength Range: 600 nm to 1700 nm
  • Wavelength Accuracy: ±0.008 nm (typical)
  • Wavelength Resolution: 0.02 nm
  • Close-in Dynamic Range: 78 dB (typical)
  • Level Range: +20 to -90 dBm
  • Up to 2x faster measurement with SMSR mode
  • Sharper spectrum measurement with HCDR mode
  • Large touchscreen LCD for easy operation and data visualization

Request a demo

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Yokogawa WT5000 – Precision Power Analyzers

    • Sample Rate: 10 MS/s
    • Power Bandwidth: 1 MHz
    • Resolution: 18 bit
    • Elements: 1-7
    • Accuracy: 0.03%
    • 10.1″ touchscreen

    Request a demo

      This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

      Yokogawa 2553A – Precision DC Calibrator

      • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
      • High resolution: 5.5 digits ±120000 count output resolution
      • DC Voltage: ±10 mV to ±30 V
      • DC Current: ±1 mA to ±100 mA
      • Voltage accuracy: +/- 75 ppm
      • Current accuracy: +/- 120 ppm
      • Temperature calibration: 10 types of thermocouples including K, T, E, and J types
      • User-defined thermocouple and RTD (PT1000) calibration: Generates various types of thermocouple and RTD by extrapolating the relation between voltage and temperature

      Yokogawa LS3300 – AC Power Calibrator

      • High Accuracy:
        • AC Voltage: ±350 ppm
        • AC Current: ±450 ppm
        • AC Power: ±450 ppm
      • Phase Accuracy: ±0.03Ëš at 50/60 Hz
      • High Stability:
        • AC voltage: ±50 ppm/h
        • AC current: ±50 ppm/h
        • AC power: ±100 ppm/h
      • Wide Generation Range:
        • AC voltage: 10 mV to 1250 V
        • AC current: 0.3 mA to 62.5 A
        • Frequency: 40 to 1200 Hz

      Yokogawa 2558A – Precision AC Standard

      • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
      • 6 voltage ranges (100 m/1/10/100/300/1000 V)
      • 4 current ranges (100 m/1/10/50 A)
      • Sweep (Voltage/Current/Frequency)
      • Output Divider: Linearity tests can be simply performed by dividing the output into steps. For example, a setting of 4 will generate steps of 25, 50, 75 and 100% of the set output value.
      • % Deviation readout
      • Common current output terminals: The same output terminals are used for all current ranges. Test times are therefore reduced by avoiding the need to change the wiring for meters which have different ranges.
      • Wide frequency range-: 40 to 1000 Hz (Frequency accuracy : ±50 ppm)

      Request a demo

        This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

        Yokogawa 2560A – Precision DC Calibrator

        • Intuitive operation: Dials and switches are provided for each digit and function, and traditional 7-segment LEDs provide clear visibility
        • High resolution: 5.5 digits ±120000 count output resolution
        • Accuracy:
          • DC voltage: ±50 ppm
          • DC current: ±70 ppm
        • Resolution:
          • 5.5 digits, ±120000 count display
          • 6.5 digits, ±1200000 count display – high res.
        • Direct readout of the deviation
        • Digital display of output
        • Output Divider
        • Sweep: With a flick of a switch, the output can be swept within the source range with sweep times of 8, 16, 32 or 64 seconds.
        • High stability
          • DC voltage: ±10 ppm/h
          • DC current: ±20 ppm/h

        Yokogawa 30032A – Clamp-on Tester

        • Leakage current measurement range from 3mA to 60A
        • Diameter of measurable conductor: 40 mm max.
        • Easier and clear display

        Yokogawa AQ1100 – Multi-function Optical Loss Test Sets

        • 5.7 inch color LCD for easy viewing
        • Multi-core fiber measurement with a pair set
        • Optional PING Test function and Visible light Source
        • Optical Power Meter Selections
          • Standard: +10 to -70dBm
          • High power: +27 to -50dBm
          • PON : 1490/1550nm Parallel measurement
        • Light Sources (3 models)
          • SM1310/1550nm
          • SM1310/1550/1625nmMM850/1300nm and SM1310