Yokogawa
Yokogawa AQ2200-332 – Optical Attenuator Module
- Compact: The AQ2200-332 features an optical variable attenuator and an optical power meter for monitoring the optical output power in a one-slot module. Ideal for bit error testing
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Attenuation accuracy: within ±0.1 dB
- With the output monitoring function, the AQ2200-332 allows direct setup of optical power at the output terminals
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-411 – Optical Switch Module
- Compact: Optical switches of 1 x 4 or 1 x 8 port configuration in a one-slot size module
- Compatible with SMF (core diameter of 10 µm) or MMF (core diameter of 62.5 µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-412 – Optical Switch Module
- Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-421 – Optical Switch Module
- Compact: Optical switches of 1 x 2 or 2 x 2 port configuration in a one-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-642 – Transceiver I/F Module
- Support 10G optical transceivers
- XFP, SFP+, XENPAK
- Power supply and power current monitoring
- Equipped with current limiter
- I2C/MDIO interface
- Signal Control
- User can define the signal names
- Voltage monitoring of status signals
- Threshold adjustment for High/Low decision
- Resistance monitoring for APS SET
Yokogawa AQ4280 – Portable Optical Light Sources
- Three-wavelengths to address telecom service, plus additional wavelength for maintenance channel.
AQ4280A ; 1310/1550nm
AQ4280B ; 1310/1490/1550nm
AQ4280C ; 1310/1550,1490/1625nm (2 ports) - Auto switching of measurement wavelength
Yokogawa AQ6373B – Visible Wavelength Optical Spectrum Analyzers
Notice: This product has been discontinued.
Replaced by Yokogawa AQ6373E.
Replaced by Yokogawa AQ6373E.
- Wavelength range: 350 to 1200nm
- Wavelength accuracy: ±0.05 nm
- Wavelength resolution: 0.02 to 10 nm and 0.01nm (400 to 470nm)
- Max safe input power: +20 dBm
- Level sensitivity: -80 dBm
- Dynamic range: ≧60dB
- Single-mode, Multimode, and Large-core fibers
- Built-in optical alignment source
- Wavelength calibration with an external reference source
- Various analysis functions including the Color analysis function for VIS
Yokogawa AQ6373E – Visible Wavelength Optical Spectrum Analyzers
- Three available models for short wavelength range applications: Standard, High Resolution, Limited
- Wavelength Range:Â 350 – 1200 nm (all models)
- Wavelength Resolution
- Standard: 0.02 nm – 10 nm
- High Resolution: 0.01 nm – 10 nm (0.01 nm from 350 – 600 nm)
- Limited: 0.1 nm – 5 nm
- Wavelength Accuracy
- Standard: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
- High Resolution: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
- Limited: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
- Close-In Dynamic Range
- Standard: 60 dB (λPK ± 0.5 nm)
- High Resolution: 60 dB (λPK ± 0.5 nm)
- Limited: 45 dB (λPK ± 0.5 nm)
- Sensitivity
- Standard: -80 dBm (500 – 1000 nm)
- High Resolution:Â -80 dBm (500 – 1000 nm)
- Limited:Â -70 dBm (500 – 1000 nm)
- Measurement Level Range
- Standard: 100 dB (-80 – +20 dBm)
- High Resolution: 100Â dBÂ (-80 – +20 dBm)
- Limited: 90Â dBÂ (-70 – +20 dBm)
- Max Safe Input Power: +20 dBm (550 to 1100 nm) +10 dBm (400 to 550 nm)Â (total input power)
- Single-mode, multimode, and large-core fibers
- Built-in optical alignment source
- Wavelength calibration with an external reference source
- Various analysis functions including color analysis for VIS
Yokogawa AQ6374 – Wide Range Optical Spectrum Analyzers
Notice: This product has been discontinued.
Replaced by Yokogawa AQ6374E.
Replaced by Yokogawa AQ6374E.
- Wavelength range: 350 to 1750nm
- High wavelength accuracy: ±0.05nm
- High wavelength resolution: 0.05 to 10 nm
- Wide dynamic range: 60dB (peak ±1.0nm)
- Wide level range: +20 to -80dBm
- Fast measurement: 0.5 sec. (100nm span)
- 8 wavelength resolution settings: 0.05 to 10 nm
- wide measurable level range is from−80 to +20 dBm
- ±0.05 nm wavelength accuracy can be maintained by the calibration
- Fast Measurement 0.5 s for 100 nm span (with sensitivity set to NORM_AUTO)
Yokogawa AQ6374E – Wide Range Optical Spectrum Analyzers
- Wide dynamic range: 60dB (peak ±1.0 nm)
- Wide level range: +20 to -80dBm
- Fast measurement: 0.5 sec. (100 nm span)
- Wide wavelength range:Â 350 –Â 1750 nm
- High wavelength resolution: 0.05 nm (full wavelength range)
- High wavelength accuracy: ±0.05 nm (633/1523 nm), ±0.2 nm (350 – 1750 nm)
- Close-in dynamic range: 60 dB (λPK ±1 nm)
- Sensitivity:Â -80 dBm (900 – 1600 nm), -70 dBm (400 – 900 nm)