Yokogawa
Yokogawa AQ2200-332 – Optical Attenuator Module
- Compact: The AQ2200-332 features an optical variable attenuator and an optical power meter for monitoring the optical output power in a one-slot module. Ideal for bit error testing
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Attenuation accuracy: within ±0.1 dB
- With the output monitoring function, the AQ2200-332 allows direct setup of optical power at the output terminals
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-411 – Optical Switch Module
- Compact: Optical switches of 1 x 4 or 1 x 8 port configuration in a one-slot size module
- Compatible with SMF (core diameter of 10 µm) or MMF (core diameter of 62.5 µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-412 – Optical Switch Module
- Compact: Optical switches of 1 x 16 port configuration in a two-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-421 – Optical Switch Module
- Compact: Optical switches of 1 x 2 or 2 x 2 port configuration in a one-slot size module
- Compatible with SMF(10/125µm) or MMF(50/125µm, 62.5/125µm)
- Low insertion loss: 1.0 dB (typ.)
- High switching reproducibility: within ±0.01 dB
- Can be combined with various AQ2200 series modules or other Yokogawa’s optical communication measuring instruments to build versatile measuring systems
Yokogawa AQ2200-642 – Transceiver I/F Module
- Support 10G optical transceivers
- XFP, SFP+, XENPAK
- Power supply and power current monitoring
- Equipped with current limiter
- I2C/MDIO interface
- Signal Control
- User can define the signal names
- Voltage monitoring of status signals
- Threshold adjustment for High/Low decision
- Resistance monitoring for APS SET
Yokogawa AQ4280 – Portable Optical Light Sources
- Three-wavelengths to address telecom service, plus additional wavelength for maintenance channel.
AQ4280A ; 1310/1550nm
AQ4280B ; 1310/1490/1550nm
AQ4280C ; 1310/1550,1490/1625nm (2 ports) - Auto switching of measurement wavelength
Yokogawa AQ6373B – Visible Wavelength Optical Spectrum Analyzers
- Wavelength range: 350 to 1200nm
- Wavelength accuracy: ±0.05 nm
- Wavelength resolution: 0.02 to 10 nm and 0.01nm (400 to 470nm)
- Max safe input power: +20 dBm
- Level sensitivity: -80 dBm
- Dynamic range: ≧60dB
- Single-mode, Multimode, and Large-core fibers
- Built-in optical alignment source
- Wavelength calibration with an external reference source
- Various analysis functions including the Color analysis function for VIS
Yokogawa AQ6374 – Wide Range Optical Spectrum Analyzers
- Wavelength range: 350 to 1750nm
- High wavelength accuracy: ±0.05nm
- High wavelength resolution: 0.05 to 10 nm
- Wide dynamic range: 60dB (peak ±1.0nm)
- Wide level range: +20 to -80dBm
- Fast measurement: 0.5 sec. (100nm span)
- 8 wavelength resolution settings: 0.05 to 10 nm
- wide measurable level range is from−80 to +20 dBm
- ±0.05 nm wavelength accuracy can be maintained by the calibration
- Fast Measurement 0.5 s for 100 nm span (with sensitivity set to NORM_AUTO)
Yokogawa AQ6375B – Long Wavelength Optical Spectrum Analyzers
- Long wavelength range: 1200 to 2400 nm
- Gas purging ports to reduce water vapor effects
- Built-In cut filter for high order diffracted light
- Double Speed Mode to further enhance fast measurement speed
- High sensitivity down to -70 dBm
- High resolution to 0.050 nm
- Wide close-in dynamic range (55dB)
- Fast auto-calibration
- Free space optical input for maximum flexibility, low maintenance, and high reliability
- Applicable to single-mode and multimode fibers
- Excellent performance for environmental gas sensing Laser Spectroscopy
- Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 2.4μm
Yokogawa AQ6375E – Long Wavelength Optical Spectrum Analyzer
- Lineup of 3 models [Standard, Extended and Limited]
- Long wavelength range:
- 1200 to 2400 nm [Standard, and Limited]
- 1000 to 2500 nm [Extended ]
- Gas purging ports to reduce water vapor effects
- Built-In cut filter for high order diffracted light *
- Double Speed Mode to further enhance fast measurement speed
- High sensitivity down to -70 dBm *
- High resolution to 0.05 nm *
- Wide close-in dynamic range (55dB) *
- Fast auto-calibration
- Free space optical input for maximum flexibility, low maintenance, and high reliability
- Applicable to single-mode and multimode fibers
- Excellent performance for environmental gas sensing Laser Spectroscopy
- Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 2.5 μm