Showing 41–50 of 112 results

Yokogawa AQ6375B – Long Wavelength Optical Spectrum Analyzers

Notice: This product has been discontinued.
Replaced by Yokogawa AQ6375E.
  • Long wavelength range: 1200 to 2400 nm
  • Gas purging ports to reduce water vapor effects
  • Built-In cut filter for high order diffracted light
  • Double Speed Mode to further enhance fast measurement speed
  • High sensitivity down to -70 dBm
  • High resolution to 0.050 nm
  • Wide close-in dynamic range (55dB)
  • Fast auto-calibration
  • Free space optical input for maximum flexibility, low maintenance, and high reliability
  • Applicable to single-mode and multimode fibers
  • Excellent performance for environmental gas sensing Laser Spectroscopy
  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 2.4μm

Yokogawa AQ6375E – Long Wavelength Optical Spectrum Analyzer

  • Lineup of 3 models [Standard, Extended and Limited]
  • Long wavelength range:
    • 1200 to 2400 nm [Standard, and Limited]
    • 1000 to 2500 nm [Extended ]
  • Gas purging ports to reduce water vapor effects
  • Built-In cut filter for high order diffracted light *
  • Double Speed Mode to further enhance fast measurement speed
  • High sensitivity down to -70 dBm *
  • High resolution to 0.05 nm *
  • Wide close-in dynamic range (55dB) *
  • Fast auto-calibration
  • Free space optical input for maximum flexibility, low maintenance, and high reliability
  • Applicable to single-mode and multimode fibers
  • Excellent performance for environmental gas sensing Laser Spectroscopy
  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 2.5 μm

*  Except Limited Model

Yokogawa AQ6376E – Three Micron Optical Spectrum Analyzer

  • Long wavelength range: 1500 to 3400 nm
  • Gas purging ports to reduce water vapor effects
  • Built-In cut filter for high order diffracted light
  • Double Speed Mode to further enhance fast measurement speed
  • High sensitivity down to -65 dBm
  • High resolution to 0.1 nm
  • Wide close-in dynamic range (55dB)
  • Fast auto-calibration
  • Free space optical input for maximum flexibility, low maintenance, and high reliability
  • Applicable to single-mode and multimode fibers
  • Excellent performance for environmental gas sensing Laser Spectroscopy
  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm

Yokogawa AQ6376 – Three Micron Optical Spectrum Analyzers

Notice: This product has been discontinued.
Replaced by Yokogawa AQ6376E.
  • Long Wavelength Range: from 1500 nm to 3400nm
  • High Sensitivity: down to -65dBm
  • Gas purging ports to reduce water vapor effects
  • Built-In cut filter for high order diffracted light
  • Double Speed Mode to further enhance fast measurement speed
  • High resolution to 0.10 nm
  • Wide close-in dynamic range: 55 dB
  • Fast auto-calibration
  • Free space optical input for maximum flexibility, low maintenance, and high reliability
  • Applicable to single-mode and multimode fibers
  • Excellent performance for environmental gas sensing Laser Spectroscopy
  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm

Yokogawa AQ6376E – Three Micron Optical Spectrum Analyzers

  • Long wavelength range: 1500 to 3400 nm
  • Gas purging ports to reduce water vapor effects
  • Built-In cut filter for high order diffracted light
  • Double Speed Mode to further enhance fast measurement speed
  • High sensitivity down to -65 dBm
  • High resolution to 0.1 nm
  • Wide close-in dynamic range (55dB)
  • Fast auto-calibration
  • Free space optical input for maximum flexibility, low maintenance, and high reliability
  • Applicable to single-mode and multimode fibers
  • Excellent performance for environmental gas sensing Laser Spectroscopy
  • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm

Yokogawa AQ6380 – High Performance Optical Spectrum Analyzers

  • Wavelength range: 1200 to 1650 nm
  • High wavelength resolution: 5 pm
  • High wavelength accuracy: ±5 pm
  • Wide close-in dynamic range: 65 dB
  • High stray-light suppression: 80 dB
  • Fully automated periodical wavelength calibration with a built-in light source
  • Semi-automated wavelength calibration with an external light source

Yokogawa AQ7280 – Modular Optical Time Domain Reflectometer

  • Dual-operation Mode – Touch screen and hard-key buttons
  • 9 OTDR units ranging from single mode to multi mode
  • Multi-tasking – Enhancing productivity
  • Lightning Startup Time, under 10 seconds
  • Multi-Fiber Measurement -Database view. Organized. Quick preview of network characteristics
  • Fault Locator
  • Modular Construction

Yokogawa CA310 – Process Calibrator

  • Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
  • 20 mA SIMULATE (SINK) function
  • Simultaneously supplies 24 V loop power and measure output signal with high accuracy
  • HART/BRAIN comm. resistance (250Ω) embedded
  • Sub display displays span% of the source value
  • Corresponds to various types of source pattern (Step sweep/ Linear sweep/ Manual step/ Span check)
  • Sources by 25% step automatically from 0% to 100% of span
  • Sources by 25% step manually from 0% to 100% of span.
  • Simple operation, easy to use
  • Rotary switch range selector
  • Linear Sweep Function
  • Lightweight, compact body
  • Span Check Function

Yokogawa CA320 – Process Calibrator

  • Basic accuracy: 0.5°C (Typical of TC type K)
    *Including accuracy of internal RJC
  • Sub display displays value of voltage source and span%
  • Corresponds to 16 types of TC standard
    (JIS/IEC/DIN/ASTM/GOST R)
  • Corresponds to various types of source pattern
    (Step sweep/ Linear sweep/ Manual step/ Span check)
  • Corresponds to other TC types by mV source function
  • Measures TC sensor output as a thermometer

Yokogawa CA330 – Process Calibrator

  • Basic accuracy: 0.3°C (Typical of PT100)
  • Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
  • Sub display displays value of resistance source and span%
  • Corresponds to various types of source pattern
    (Step sweep/ Linear sweep/ Manual step/ Span check)
  • Corresponds to 2,3,4 wire. Realizes RTD simulation
  • Measures output of RTD sensor as a thermometer
  • Sources by 25% step automatically from 0% to 100% of span
  • Sources by 25% step manually from 0% to 100% of span.
  • Simple operation, easy to use
  • Rotary switch range selector
  • Linear Sweep Function
  • Lightweight, compact body
  • Span Check Function