Displays
Eagle Signal B866 Series – Multi-Function Analog Timer
- Field selectable for operation in On-Delay, Off-Delay*, Interval, or Repeat Cycle modes
- Universal power supply accepts 24 – 240 VAC or 24 VDC
- Meets IEC 801 level 4 noise immunity standards
- Unique On-Delay/Interval model lets one unit do the work of two in many applications
- Industry standard socket connection
- Front panel or DIN rail mounting
- Flexible start and reset input signals
- UL, CUL recognized, CE compliant
- IP54 rated front panel – ideal for harsh environments
Eagle Signal CX200 & CX300 Series – Flex Timer Counter
- Five time ranges from 19.999 sec. to 199 hrs.: 59 min.
- Two count rates – accept and display counts from 1 to 19999
- Two relay outputs – socket mounted for easy replacement
- Two form C instantaneous contacts and two form C programmed contacts
- N.O. solid state MOSFET, delayed action switch rated at 1 ampere continuous load current, 0-264 VAC 50/60 Hz or DC
- Ideal output for switching low level signals and high voltage loads due to MOSFET output’s ON resistance of 0.5 ohm and very low OFF leakage
- Programmed outputs operate in one of four load sequences; OOX, OXO, OOX with pulse output, and OOX pulse output with repeat cycle operation
- Standard start is defined as ON delay reset timer or counter
- For standard start units, timer/counter resets on power failure
- Reverse start or OFF delay units will not reset on power failure and will continue cycle when power is restored
- Non-volatile memory data retention
Eagle Signal HP5 Series – Cycle Flex Reset Timer
- 16 standard time ranges from 5 seconds to 60 hours
- Knob adjustable time ranges – progress pointer for each
- Highly visible, calibrated dials (7.85 inch circumference)
- Easily read and well-spaced calibrations
- Red progress pointer displays remaining time interval
- Pilot light indicates when timer motor is energized
- Standard timers supplied with “power on” clutch operation
- Optional reverse action clutch will not reset on power failure
- 15 terminal ABS (UL rated 94V-0) molded housing has high impact resistance and will not support combustion
Eagle Signal HQ4 Series – Percentage Timer
- Panel Mount
- Settings may be made or set during timer operation
- Designed for applications where ON time of a fixed cycle needs to be variable.
- UL/CUL Recognition E61735
Eagle Signal HQ9 Series – Percentage Timer
- Panel Mount
- Electrically isolated pilot light
- Cycle progress pointer
- Compatible with CYCL-FLEX® series featuring unique plug-in mounting
- UL Recognition E61735 CSA Certification LR26861
Eagle Signal MAX Count Series – 16 Preset Advanced Counters
- Simultaneous Counter, Totalizer, and Batching
- “ON THE FLY” Preset Programming
- A-B, A+B and Quadrature operation
- Sixteen Preset, Six Decade Main Counter
- Single Preset, Six Decade Batch Counter
- Six Decade Background Totalizer
- 4 Wire / 2 Wire RS-485 Provides LOCAL & REMOTE process Control Capability with Modbus RTU protocol
- Six Decade Start Count Preset
- Counter Reset, Stop / Hold / (*Step Back) Inputs
Eagle Signal MAX Position Advanced Series – Advanced Position Indicator
- Bidirectional (go thru zero) counter
- Non-Volatile counter operation.
- Four user programmable preset setpoints
- Programmable reference setpoint
- Programmable Operation; A-B, A+B, Quad
- Programmable 6 decade correction constant
- Selectable Input logic; x1, x2 and x4
- STOP/HOLD, REFERENCE ENABLE, OUTPUT DISABLE and REFERENCE Control inputs
- 4 Wire / 2 Wire RS-485 Provides LOCAL and REMOTE process Control Capability Modbus RTU protocol
- FRAM Memory for Setpoint storage
- Built In Self- Diagnostics
- Eight Alpha Numeric, 14 Segments LED display
Eagle Signal MAX Tach Series – Tachometers
- Time Interval Measurement Technique
- Dual High speed Rate Inputs
- Automatic Averaging
- Dual Programmable Calibrators on Rate inputs
- Programmable Rate and Draw Display modes
- Control Inputs (Unlatch and Disable)
- Six Solid State Alarm Outputs
- 4 Wire / 2 Wire RS-485 Provides LOCAL and REMOTE process Control Capability Modbus RTU protocol
- Non-Volatile Memory (FRAM) for Programmed parameters
- Built In Self- Diagnostics
- Eight Alpha Numeric, 14 Segments LED display
Eagle Signal SX Series – Preset Counters
- NEMA 4 Hosedown Test rated
- Eight output operating modes programmable for one or both outputs
- Programmable Early Trip pre-warn operation
- Time inhibit input
- LED indicators for output status
- Setpoint to zero or zero to setpoint cycle progress indication
- Front panel and remote reset inputs
- Keypad lock function
- Nonvolatile memory (NOVRAM) for program and data retention
- Removable terminal blocks for wiring connections
- +12 VDC, 75 milliamp sensor power supply
Veeder-Root 7437 Series – Electro-Mechanical Totalizer
- Non-resettable
- Broad range of standard AC and DC models
- Base mount and panel mount styles
- High contrast white-on-black figures
- cUL recognized; CSA certified
- Tamper resistant construction
- Capable of speeds to 600 counts/minute
- Thermo-stable materials used for long term reliability