Optical Spectrum Analyzers (also known as OSA) are prevision instruments that have been designed to measure and display the power distribution of an optical source over a specified wavelength span. The optical analyzer spectrum trace shows wavelength in the horizontal scale and power on the vertical scale.

The expanding field of optics-related applications has created a variety of industries and organizations that require advanced optical spectral measurements for both R&D and manufacturing. These industries include telecommunications, consumer electronics, healthcare, life science/medical research, security, sensing, microscopy, and gas/chemical analysis, and environmental monitoring.

Showing all 8 results

Yokogawa AQ6360 – Telecom Optical Spectrum Analyzers

  • Wavelength range: 1200 to 1650 nm
  • Wavelength resolution: 0.1 to 2 nm
  • High wavelength accuracy: ±0.02 nm
  • High dynamic range: 55 dB
  • Wide measurement range: +20 to −80 dBm

Yokogawa AQ6370E – Telecom Optical Spectrum Analyzers

  • Wavelength Range: 600 nm to 1700 nm
  • Wavelength Accuracy: ±0.008 nm (typical)
  • Wavelength Resolution: 0.02 nm
  • Close-in Dynamic Range: 78 dB (typical)
  • Level Range: +20 to -90 dBm
  • Up to 2x faster measurement with SMSR mode
  • Sharper spectrum measurement with HCDR mode
  • Large touchscreen LCD for easy operation and data visualization

Request a demo

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Yokogawa AQ6373E – Visible Wavelength Optical Spectrum Analyzers

    • Three available models for short wavelength range applications: Standard, High Resolution, Limited
    • Wavelength Range: 350 – 1200 nm (all models)
    • Wavelength Resolution
      • Standard: 0.02 nm – 10 nm
      • High Resolution: 0.01 nm – 10 nm (0.01 nm from 350 – 600 nm)
      • Limited: 0.1 nm – 5 nm
    • Wavelength Accuracy
      • Standard: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
      • High Resolution: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
      • Limited: ±0.05 nm (633 nm), ±0.2 nm (400 – 1100 nm)
    • Close-In Dynamic Range
      • Standard: 60 dB (λPK ± 0.5 nm)
      • High Resolution: 60 dB (λPK ± 0.5 nm)
      • Limited: 45 dB (λPK ± 0.5 nm)
    • Sensitivity
      • Standard: -80 dBm (500 – 1000 nm)
      • High Resolution: -80 dBm (500 – 1000 nm)
      • Limited: -70 dBm (500 – 1000 nm)
    • Measurement Level Range
      • Standard: 100 dB (-80 – +20 dBm)
      • High Resolution: 100 dB (-80 – +20 dBm)
      • Limited: 90 dB (-70 – +20 dBm)
    • Max Safe Input Power: +20 dBm (550 to 1100 nm) +10 dBm (400 to 550 nm) (total input power)
    • Single-mode, multimode, and large-core fibers
    • Built-in optical alignment source
    • Wavelength calibration with an external reference source
    • Various analysis functions including color analysis for VIS

    Yokogawa AQ6374E – Wide Range Optical Spectrum Analyzers

    • Wide dynamic range: 60dB (peak ±1.0 nm)
    • Wide level range: +20 to -80dBm
    • Fast measurement: 0.5 sec. (100 nm span)
    • Wide wavelength range: 350 – 1750 nm
    • High wavelength resolution: 0.05 nm (full wavelength range)
    • High wavelength accuracy: ±0.05 nm (633/1523 nm), ±0.2 nm (350 – 1750 nm)
    • Close-in dynamic range: 60 dB (λPK ±1 nm)
    • Sensitivity: -80 dBm (900 – 1600 nm), -70 dBm (400 – 900 nm)

    Yokogawa AQ6375E – Long Wavelength Optical Spectrum Analyzer

    • Lineup of 3 models [Standard, Extended and Limited]
    • Long wavelength range:
      • 1200 to 2400 nm [Standard, and Limited]
      • 1000 to 2500 nm [Extended ]
    • Gas purging ports to reduce water vapor effects
    • Built-In cut filter for high order diffracted light *
    • Double Speed Mode to further enhance fast measurement speed
    • High sensitivity down to -70 dBm *
    • High resolution to 0.05 nm *
    • Wide close-in dynamic range (55dB) *
    • Fast auto-calibration
    • Free space optical input for maximum flexibility, low maintenance, and high reliability
    • Applicable to single-mode and multimode fibers
    • Excellent performance for environmental gas sensing Laser Spectroscopy
    • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 2.5 μm

    *  Except Limited Model

    Yokogawa AQ6376E – Three Micron Optical Spectrum Analyzer

    • Long wavelength range: 1500 to 3400 nm
    • Gas purging ports to reduce water vapor effects
    • Built-In cut filter for high order diffracted light
    • Double Speed Mode to further enhance fast measurement speed
    • High sensitivity down to -65 dBm
    • High resolution to 0.1 nm
    • Wide close-in dynamic range (55dB)
    • Fast auto-calibration
    • Free space optical input for maximum flexibility, low maintenance, and high reliability
    • Applicable to single-mode and multimode fibers
    • Excellent performance for environmental gas sensing Laser Spectroscopy
    • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm

    Yokogawa AQ6376E – Three Micron Optical Spectrum Analyzers

    • Long wavelength range: 1500 to 3400 nm
    • Gas purging ports to reduce water vapor effects
    • Built-In cut filter for high order diffracted light
    • Double Speed Mode to further enhance fast measurement speed
    • High sensitivity down to -65 dBm
    • High resolution to 0.1 nm
    • Wide close-in dynamic range (55dB)
    • Fast auto-calibration
    • Free space optical input for maximum flexibility, low maintenance, and high reliability
    • Applicable to single-mode and multimode fibers
    • Excellent performance for environmental gas sensing Laser Spectroscopy
    • Indispensable tool for R&D and manufacturing of optical devices in the wavelength range from telecom band to 3.4μm

    Yokogawa AQ6380 – High Performance Optical Spectrum Analyzers

    • Wavelength range: 1200 to 1650 nm
    • High wavelength resolution: 5 pm
    • High wavelength accuracy: ±5 pm
    • Wide close-in dynamic range: 65 dB
    • High stray-light suppression: 80 dB
    • Fully automated periodical wavelength calibration with a built-in light source
    • Semi-automated wavelength calibration with an external light source