Low Voltage
GE / ITI 3P81 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 1.63″
GE / ITI 3P82 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.00″
GE / ITI 3P83 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 1.55″ x 0.45″
GE / ITI 3P84 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.05″ x 0.50″
GE / ITI 3P85 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.08″
GE / ITI 3P86 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 1.55″ x 0.25″
GE / ITI 3P9 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 1.25″ x 0.25″ Full Radius
GE / ITI 3P90 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 1.63″
GE / ITI 3P91 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.12″
GE / ITI 3P92 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.56″ x 2.12″
GE / ITI 3P93 Series – Low Voltage Current Transformers
- Frequency: 50-400 Hz
- Insulation Level: 600 Volts, 10 kV BIL full wave
- Window Size: 2.88″
GE / ITI 3VT468 Series – 3-Phase Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 75 VA at 30C/50 VA at 55C
- Accuracy Class: ± 0.6% @ 7.5 VA
GE / ITI 3VT471 Series – 3-Phase Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 40 VA at 30C/27 VA at 55C
- Accuracy Class: ±1% @ 5 VA
GE / ITI 3VT472 Series – 3-Phase Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 40 VA at 30C/27 VA at 55C
- Accuracy Class: ± 1% @ 5 VA
GE / ITI 3VTL460 Series – 3-Phase Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V line-to-line
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 150 VA at 30C/100 VA at 55C
- Accuracy Class: 0.6 W, 1.2 X at 60 Hz
GE / ITI 3VTN460 Series – 3-Phase Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 150 VA at 30C/100 VA at 55C
- Accuracy Class: 0.6 W, 1.2 X at 60 Hz
GE / ITI 450 Series – Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 750 VA at 30C/500 VA at 55C
- Accuracy Class: 0.3 W, X, M & Y, 1.2Z
Those marked ** are 0.3 W, 0.6 X, M & Y
GE / ITI 450I Series – IEC Rated 50 Hz Voltage Transformers
- Frequency: 50 Hz
- Standard Secondary Voltage: 110 Volts
- Insulation Level: 720 Volts
- Accuracy Class: 0.2 at 40 VA / 0.5 at 70 VA
- Thermal Rating: 550 VA at 30C / 350 VA at 55C
GE / ITI 460 Series – Voltage Transformers
- Frequency: 60 Hz
- Standard Secondary Voltage: 120 V
- Insulation Level: 600 V, BIL 10 kV
- Thermal Rating: 150 VA at 30C/100 VA at 55C
- Accuracy Class: 0.6 W, 1.2 X at 60 Hz
GE / ITI 460I Series – IEC Rated 50 Hz Voltage Transformers
- Frequency: 50 Hz
- Standard Secondary Voltage: 110 Volts
- Insulation Level: 720 Volts
- Accuracy Class: 0.5 at 10 VA / 1.0 at 20 VA
- Thermal Rating: 125 VA at 30C / 75 VA at 55C