ITECH IT7900EP Series – High Performance Regenerative Grid Simulator

With the adoption of advanced SiC technology, the IT7900EP series high-performance regenerative grid simulator offers a comprehensive test solution. This versatile device functions not only as a grid simulator and four-quadrant power amplifier but also as a four-quadrant regenerative AC/DC electronic load. Its full four-quadrant operation and regenerative capability enable power feedback to the grid, promoting environmental sustainability and significantly reducing electricity and heat dissipation costs.

Designed with a compact, modular, and efficient structure, the IT7900EP delivers up to 21kVA in a 3U single unit, and its power can be extended to 1MVA through master-slave parallel connection. The colorful touch screen with an intuitive GUI allows users to directly define various waveforms. The simulator supports a wide range of operational modes, accommodating single-phase, three-phase, and reverse-phase testing requirements. This high flexibility makes it suitable for applications in PV, ESS, and EV industries.

Request a demo

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    SEND US A MESSAGE

      This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

      CONTACT INFORMATION

      900 McKay Road, Unit 2
      Pickering, Ontario
      Canada, L1W 3X8

      Phone: (905) 428-3413
      Toll Free: (800) 617-3413

      sales@electro-meters.com

      Do you have questions about how we can help your company? Send us an email and we’ll get in touch shortly.

      Description

      Parameter Features

      • Adopt advanced SiC technology
      • High power density, up to 21 kVA for 3U
      • Voltage can reach 350V L-N
      • Highly efficient power regeneration
      • Master and slave equal flow, parallel machines up to 1MVA
      • Comprehensive working modes selectable: single-phase, three-phase, reversed phase, and multi-channel; voltage extension to 200% of rated voltage in reversed mode
      • Support LIST/SWEEP/Surge&Sag three waveform modes
      • Built-in rich waveform database
      • Harmonic simulation and analysis function up to 50 times, built-in IEC61000-3-2/3-12 compliance
      • Can simulate arbitrary waveform output, support CSV file import waveform
      • Phase angle 0-360° settable
      • Touch screen design, simple UI interface
      • Built-in USB/CAN/LAN/Digital IO interface, optional GPIB/analog & RS232 interface
      • Full protection functions including automatic clearing, POVP, watchdog, etc. Support CANopen, Modbus, LXI, SCPI communication

      Source Features

      • Regenerative grid simulator & full 4-quadrant AC & DC power sources
      • Frequency: 16-2400Hz
      • Power amplifier function for PHIL applications
      • Four output modes: AC/DC, AC+DC, DC+AC
      • Programmable output impedance, simulation of real-world impedance
      • Harmonic/inter-harmonic synthesis
      • Compliance tests including LVRT, Phase Jump, Frequency Variation, harmonic injection
      • Supported regulatory testing includes IEC61000-4-11/4-13/4-14/4-28
      • Optional software to complete pre-compliance standards testing for civil avionics/electrical ships according to multinational safety regulations

      Load Features

      • Regenerative full 4-quadrant AC & DC load
      • Frequency: 16-500Hz
      • AC mode supports CC/CP/CR/CS/CC+CR/CE multiple operating modes, and CE mode can simulate various circuit topologies such as single-phase rectifier RLC and shunt RLC
      • DC mode supports 9 working modes including CC/CR/CP/CV
      • AC mode supports both rectified and non-rectified modes
      • Adjustable crest factor: 1.414 ~ 5.0
      • Support phase shift function in the range of -180º ~ 180º
      • The unit power factor function allows the current waveform to vary with the voltage waveform, making the power factor as close to 1 as possible
      • Supporting unloading angle control, 0-359° adjustable

      *Notes:*

      1. Voltage/current harmonic analysis, voltage harmonic simulation in source mode, current harmonic simulation in load mode, fundamental wave ≤ 60Hz
      2. Stay tuned
      3. In grid simulator and islanding simulation mode, 16-150Hz
      4. After turning on the rectification function, the setting range of the phase shift is restricted by the crest factor

      Testing Capabilities

      Power Hardware-in-the-Loop (PHiL) for Testing and Verification of Grid-Tied DUT

      ITECH modular and scalable IT7900(P) support  built-in power amplifier mode for Power Hardware in the Loop (PHIL) applications providing further testing and simulation capability.

      The lately upgraded analog interface card IT-E177 for HIL application bandwidth reaches 2.4kHz; IT7900(P) Power Amplifier mode for PHIL application with low latency at 65μs  , rising/fall high speed up to 2.5V/μs,which helps simulate real-world conditions.

      Additional information
      Approvals

      SPE-1000