Parameter Features
- High power density, up to 6 kVA for 2U and 15 kVA for 3U
- Voltage can reach 350V L-N
- Master and slave equal flow, parallel machines up to 960kVA 1
- Highly efficient energy return
- Comprehensive working modes selectable: single-phase, three-phase, reversed phase and multi-channel, Voltage extension to 200% of rated voltage in inverted mode
- Support LIST/SWEEP/Surge&Sag three waveform modes
- Harmonic simulation and analysis function up to 50 times 2
- Built-in rich waveform database
- Can simulate arbitrary waveform output, support CSV file import waveform
- Phase angle 0~359°settable
- Touch screen design, simple UI interface
- Built-in USB/CAN/LXI compliant LAN /Digital IO interface, optional GPIB/analog & RS232 interface
- A variety of protection functions, including automatic clearing protection, transient overvoltage protection POVP
- Software watchdogs, etc.
Source Features
- Regenerative grid simulator & full 4-Quadrant AC&DC power sources
- Output frequency: 16-1400Hz
- Power Amplifier function for PHiL applications
- Professional islanding test mode, support R, L, C and active, reactive power settings
- Four output modes of AC/DC/AC+DC/DC+AC can be realized
- Multi-channel function, single unit can test 1-3 DUTs at the same time 3
- Programmable output impedance, simulation of real-world impedance
- Harmonic/inter harmonic synthesis
- Frequency lock and phase lock function to achieve 6 phase& 12 phase power output
- Compliance tests incl. LVRT (Low Voltage Ride Through)/HVRT (High Voltage Ride Through)/Phase Jump/Frequency variation/harmonic injection
- Supported regulatory testing include IEC61000-4-11/4-13/4-14/4-28 etc.
- Provide rich trigger configuration, synchronous capture of the voltage waveform of the object to be measured, to achieve data acquisition and simulation functions
Load Features
- Regenerative full 4-Quadrant AC&DC load
- Output frequency: 16-500Hz
- AC mode supports CC/CP/CR/CS/CC+CR/CE multiple operating modes, and CE mode can simulate a variety of circuit topologies such as single-phase rectifier RLC and shunt RLC.
- DC mode supports 9 working modes such as CC/CR/CP/CV
- AC mode supports both rectified and non-rectified modes
- Adjustable crest factor: 1.414 ~ 5.0
- Support phase shift function in the range of -180º~180.0º 4
- When the three-phase AC, support Y and Δ two kinds of access, Y type connection when the support C-phase phase loss function
- Support with load-on
- Support positive or negative half-cycle pull load
- The unit power factor1 function allows the current waveform to vary with the voltage waveform and the power factor is as close to 1 as possible
- 3U model only
- Voltage/current harmonic analysis, voltage harmonic simulation in source mode, current harmonic simulation in load mode
- Multi-channel function is not available for single-phase models
- When rectification function is turned on, the setting range of phase shift is bounded by the peak factor
Testing Capabilities
Power Hardware-in-the-Loop (PHiL) for Testing and Verification of Grid-Tied DUT
ITECH modular and scalable IT7900(P) support built-in power amplifier mode for Power Hardware in the Loop (PHIL) applications providing further testing and simulation capability.
The lately upgraded analog interface card IT-E177 for HIL application bandwidth reaches 2.4kHz; IT7900(P) Power Amplifier mode for PHIL application with low latency at 65μs  , rising/fall high speed up to 2.5V/μs,which helps simulate real-world conditions.